Application
BK-DTS series electric power UPS, DBW Bypass Stable Cabinet and PD
series feedback cable cabinet are designed based on power plant,
transformer substation and distribution house. They have double
conversion on line and zero transfer time. And they are applied to
power equipment, RTU, power carrier wave and monitor etc. When line
is normal, single phase (220V) and 3 phases (380V) supply stable
power to load after isolation and filter. When line is abnormal or
off, switches to inverter and supply power to load. When DC switch
mode rectifier are low voltage or off, static switch switches to
bypass. When line restore normally, automatically switch line.
Inverter is overload or failed, switch to bypass. And it alarms and
send signal
It applies to power plant, transformer substation, distribution
house etc.
Feature benefits
Adopts DSP technology
Intelligently testing and monitoring
Digital Control Static Switch and zero transfer time
The fifth generation IGBT driving inverter.
Inactive contact and RS232/485
Full isolation input
DC switch mode rectifier and line are full isolated.
Adopts electric power standard cabinet to design
Full protections including over voltage, low voltage, over current
and short circuit etc
Large LCD display and user-friendly
Meter indicators.
Over 256 History record so that user analyzes and manages
Rectifier
Line (single phase and tri phase) directly send to rectifier after
isolation transformer. When line is within ±10% and load is within
100%, DC voltage stabilizes within ±1%.
Inverter
It adopts SPWN technology. The DC voltage switches AC voltage with
sine wave through IGBT module inverter. It may reduce distortion to
the extend and volume of filtering. So it keep good dynamic
characteristics when load changes.
DC switch mode rectifier
When line is low voltage and failed, DC switch mode rectifier will
supply power uninterruptedly. It sends signal in discharging mode.
When battery voltage is lower than discharging final voltage, it
will switch to standby power equipment. When battery voltage is
close to discharging final voltage, it will send warning signal.
Line and standby power
There are two loop AC voltages. When line is abnormal or failed,
will switch to standby power equipment. When they are failed, will
switch to DC mode rectifier.
Static switch
Intelligent monitor
UPS status and transmissions will be sent to DCS system through
RS232/RS485 and inactive contact. So it will be intelligent
monitor.